Submitted file = 98241dat.wb1 Cruise: Surv-1998-241 Ship: R/V Laurentian Chief Scientist: Jim Cotner PI: Tom Johengen Ph#: 734-741-2203 Email: tom.johengen@noaa.gov Data type: Particulate and dissolved nutrients on discrete water samples Total Dissolved Phosphorus (TDP) : molybdate/ascorbic acid method on AutoAnalyzer II, after persulfate digestion of 0.2 uM filtered samples Particulate Phosphorus (PP) : molybdate/ascorbic acid method on AutoAnalyzer II, after combustion, boiling HCL extraction of particles retained on a GFF filter Soluble Reactive Phosphorus (SRP) : molybdate/ascorbic acid method on AutoAnalyzer II, of 0.2 uM filtered samples Nitrate + Nitrite (NO3): cadium reduction method on AutoAnalyzer II, of 0.2 uM filtered samples Ammonium (NH4): phenol method on AutoAnalyzer II, of 0.2 uM filtered samples Summary of Analytical Precision PP avg. coeff of variance on analytical reps = 9.3% (n=44 pairs) TDP avg. coeff of variance on field reps = 16.5% (n=36 pairs) SRP avg. coeff of variance on field reps = 44% (n=36 pairs) NO3 avg. coeff of variance on field reps = 1.3% (n=20 pairs) NH4 avg. coeff of variance on field reps = 19.6% (n=20 pairs)