Gerald Miller, Michael McCormick, James Saylor Great Lakes Environmental Research Lab 2205 Commonwealth Blvd. Ann Arbor, MI 48105 Phone: 734/741-2119, 734/741-2277, 734/741-2118 FAX: 734/741-2055 Email: michael.mccormick@noaa.gov C. R. Murthy, Jim Bull National Water Research Institute Burlington, L7R4A6, Canada Email: raj.murthy@CCIW.ca, Jim.Bull@CCIW.ca GLERL Acoustic Doppler Current Profiler (ADCP) Moorings 1999-2000 Manufacturer: RD Instruments, 9855 Businesspark Ave., San Diego, CA 92131-1011 Explanation of Columns in the Data Set Ensemble Header: YR Year DOY Day of year (UT) TIME Universal time (UT - Hours and minutes HHMM) WT Water Temperature at the transducer (C) Depth cell data top to bottom: Dpth Mid-cell depth (m) E Eastward component of horizontal current (cms-1) N Northward component of horizontal current (cms-1) W Vertical velocity (cms-1) ECH Echo intensity, mean of the four beams(dB)(sonar eq. not applied) Data Sources: # Depth Filename Mooring Lat(N) Lon(W) Sensor S/N cells Dates Water/ADCP OP # A1-99-20.txt A1-99 42 05.96' 86 33.51' WH-ADCP-300 0163 13 10/20/99-04/18/00 20.0/17.8 S1999293.02 A2-99-39.txt A2-99 42 06.79' 86 38.48' WH-ADCP-300 1057 31 10/20/99-06/19/00 39.0/36.8 S1999293.01 A3b-99-28.txt A3b-99 42 09.52' 86 35.00' WH-ADCP-1200 0376 22 10/19/99-06/19/00 28.0/25.8 S1999292.04 A4-99-19.txt A4-99 42 10.38' 86 29.37' WH-ADCP-1200 0218 14 10/19/99-05/17/00 18.5/17.5 S1999292.05 A5-99-40.txt A5-99 42 13.78' 86 36.85' WH-ADCP-300 0717 33 10/19/99-06/15/00 40.0/37.8 S1999292.02 A6-99-60.txt A6-99 42 25.18' 86 31.89' WH-ADCP-300 0155 50 10/28/99-06/15/00 59.5/57.3 S1999301.01 A7-99-11.txt A7-99 42 05.60' 86 30.78' WH-ADCP-1200 0182 7 10/29/99-05/17/00 10.5/09.5 S1999301.02 CM1-99-155.txt CM1-99 42 13.75' 86 36.82' WH-ADCP-300 0703 33 06/02/99-06/19/00 155./153. S1999153.04 WH-ADCP 300kHz: Frequency: 307200 Hz Configuration: 4-beam, Convex Beam Angle: 20 degrees Orientation: Up CPU Firmware: 8.19 Depth Cell Size: 1 m Blank After Transmit:176 cm Pings/Ensemble: 180 Std Deviation: 0.8 cms-1 Time/Ensemble: 30-minutes Velocity: Accuracy +_0.5%+_0.5 cms-1 Temperature: Accuracy +-0.4oC Resolution 0.01o Compass: Long-term Accuracy +-5o Resolution 0.01o Echo Intensity Uncertainty +-1.5 dB (relative) WH-ADCP 1200kHz: Frequency: 1228800 Hz Configuration: 4-beam, Convex Beam Angle: 20 degrees Orientation: Up CPU Firmware: 8.18 Depth Cell Size: 1 m Blank After Transmit:044 cm Pings/Ensemble: 200 Std Deviation: 0.8 cms-1 Time/Ensemble: 30-minutes Velocity: Accuracy +_0.5%+_0.5 cms-1 Temperature: Accuracy +-0.4oC Resolution 0.01o Compass: Long-term Accuracy +-5o Resolution 0.01o Echo Intensity Uncertainty +-1.5 dB (relative)