Deployment parameters of Cleveland ADCP - predeployment June 1, 2013: [BREAK Wakeup A] WorkHorse Broadband ADCP Version 50.40 Teledyne RD Instruments (c) 1996-2010 All Rights Reserved. >ps0 Instrument S/N: 6232 Frequency: 614400 HZ Configuration: 4 BEAM, JANUS Match Layer: 10 Beam Angle: 20 DEGREES Beam Pattern: CONVEX Orientation: UP Sensor(s): HEADING TILT 1 TILT 2 DEPTH TEMPERATURE PRESSURE Pressure Sens Coefficients: c3 = -2.628818E-13 c2 = +2.281832E-08 c1 = +1.584239E-02 Offset = -6.195817E+00 Temp Sens Offset: -0.40 degrees C CPU Firmware: 50.40 [0] Boot Code Ver: Required: 1.16 Actual: 1.16 DEMOD #1 Ver: ad48, Type: 1f DEMOD #2 Ver: ad48, Type: 1f PWRTIMG Ver: 85d3, Type: 4 Board Serial Number Data: 2C 00 00 03 AC FB B2 09 DSP727-2001-03G EA 00 00 03 AD 2E E7 09 REC727-1000-03E 00 00 00 03 B5 D9 9F 09 CPU727-2000-00J 77 00 00 03 B5 A6 DF 09 PIO727-3000-00C >ol FEATURES --------------------------------------------------------------------- Feature Installed --------------------------------------------------------------------- BT-HA (High Accuracy 0.4%) No Water Profile Yes High Resolution Water Modes No LADCP/Surface Track/WM15 No Wave Gauge Acquisition Yes Shallow Bottom Mode No High Rate Pinging No Narrow Bandwidth only (WB1) No BT-RA (Reduced Accuracy 1.15%) No See your technical manual or contact TRDI for information on how to install additional capability in your WorkHorse. >? Available Menus: DEPLOY? ------------------ Deployment Commands SYSTEM? ------------------ System Control, Data Recovery and Testing Commands >deploy? Deployment Commands: CF = 11111 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec) CK ----------------------- Keep Parameters as USER Defaults CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY) CS ----------------------- Start Deployment EA = +00000 -------------- Heading Alignment (1/100 deg) EB = +00000 -------------- Heading Bias (1/100 deg) ED = 00260 --------------- Transducer Depth (0 - 65535 dm) ES = 35 ------------------ Salinity (0-40 pp thousand) EX = 11111 --------------- Coord Transform (Xform: Type,Tilts,3 Bm,Map) EZ = 1111101 ------------- Sensor Source (C,D,H,P,R,S,T) RE ----------------------- Recorder ErAsE RN ----------------------- Set Deployment Name TE = 00:12:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100) TF = **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec) TP = 00:14.00 ------------ Time per Ping (min:sec.sec/100) TS = 13/05/01,17:04:33 --- Time Set (yr/mon/day,hour:min:sec) WD = 111 100 000 --------- Data Out (Vel,Cor,Amp; PG,St,P0; P1,P2,P3) WF = 0088 ---------------- Blank After Transmit (cm) WN = 061 ----------------- Number of depth cells (1-128) WP = 00050 --------------- Pings per Ensemble (0-16384) WS = 0050 ---------------- Depth Cell Size (cm) WV = 175 ----------------- Mode 1 Ambiguity Vel (cm/s radial) >system? System Control, Data Recovery and Testing Commands: AC ----------------------- Output Active Fluxgate & Tilt Calibration data AF ----------------------- Field calibrate to remove hard/soft iron error AR ----------------------- Restore factory fluxgate calibration data AX ----------------------- Examine compass performance AZ ----------------------- Zero pressure reading CB = 411 ----------------- Serial Port Control (Baud; Par; Stop) CP # --------------------- Polled Mode (0 = NORMAL, 1 = POLLED) CZ ---------------------- Power Down Instrument FC ----------------------- Clear Fault Log FD ----------------------- Display Fault Log OL ----------------------- Display Features List PA ----------------------- Pre-Deployment Tests PC1 ---------------------- Beam Continuity PC2 ---------------------- Sensor Data PS0 ---------------------- System Configuration PS3 ---------------------- Transformation Matrices RR ----------------------- Recorder Directory RF ----------------------- Recorder Space used/free (bytes) RY ----------------------- Upload Recorder Files to Host >c? CB = 411 ----------------- Serial Port Control (Baud [4=9600]; Par; Stop) CC = 000 000 000 --------- Choose External Devices (x;x;x x;x;x x;x;SBMC) CF = 11111 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec) CK ----------------------- Keep Parameters as USER Defaults CP = 0 ------------------- PolledMode (1=ON, 0=OFF; BREAK resets) CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY) CS ----------------------- Go (Start Pinging) CZ ----------------------- Power Down Instrument >cd? CD = 000 000 000 --------- Serial Data Out (Vel;Cor;Amp PG;St;P0 P1;P2;P3) >hr01:00:00.00 >ht00:00:00.50 >h? Available Commands: HB 05 ------------------ Number of Automatically Choosen Bins (20 Max) HD 111000000 ----------- Waves Selected Data (Vel;Pres;Surf HPR;; ;;) HF 00000 --------------- Waves Flow Ctrl (Res;Res;Res;Ser;Rec) HP 2400 ---------------- Number of Pings per Record HR --------- Time between Wave Bursts (hh:mm:ss.ff) HS 001,010,021,022,023 - Bins selected for Directional wave data recording HT --------- Time between Wave Pings (hh:mm:ss.ff) HV 001,010,021,022,023 - Bins selected for Velocity Spectrum data recording H? --------------------- Display Waves Menu Help >pd? PD = 00 ------------------ Data Stream Select (0-18) >t? Available Commands: TB 00:00:00.00 --------- Time per Burst (hrs:min:sec.sec/100) TC 00000 --------------- Ensembles Per Burst (0-65535) TE 00:12:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100) TF **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec) TG ****/**/**,**:**:** - Time of First Ping (CCYY/MM/DD,hh:mm:ss) TP 00:14.00 ------------ Time per Ping (min:sec.sec/100) TS 13/05/01,17:06:49 --- Time Set (yr/mon/day,hour:min:sec) TT 2013/05/01,17:06:49 - Time Set (CCYY/MM/DD,hh:mm:ss) TX 00:00:00 ------------ Buffer Output Period: (hh:mm:ss) T? --------------------- Display Time Help >w? Available Commands: WD 111100000 ----------- Data Out (Vel;Cor;Amp PG;St;P0 P1;P2;P3) WF 0088 ---------------- Blank After Transmit (cm) WG 000 ----------------- Percent Good Minimum (1-100%) WN 061 ----------------- Number of depth cells (1-255) WP 00050 --------------- Pings per Ensemble (0-16384) WS 0050 ---------------- Depth Cell Size (cm) WV 175 ----------------- Mode 1 Ambiguity Vel (cm/s radial) WZ 010 ----------------- Mode 5 Ambiguity Velocity (cm/s radial) W? --------------------- Display Water-Profile Help >wa? WA 050,001 ------------- False Target Threshold (Max)(0-255),[Start Bin] >wb? WB 0 ------------------- Bandwidth Control (0=Wid,1=Nar) >wc? WC 064 ----------------- Correlation Threshold >we? WE 2000 ---------------- Error Velocity Threshold (0-5000 mm/s) >wl? WL 001,005 ------------- Water Reference Layer: Begin Cell (0=OFF), End Cell >rr Recorder Directory: Volume serial number for device #0 is 1564-0eec No files found. Bytes used on device #0 = 0 Volume serial number for device #1 is 1564-0eec No files found. Bytes used on device #1 = 0 Total capacity = 878886912 bytes Total bytes used = 0 bytes in 0 files Total bytes free = 878886912 bytes >ck [Parameters saved as USER defaults] >pa PRE-DEPLOYMENT TESTS CPU TESTS: RTC......................................PASS RAM......................................PASS ROM......................................PASS RECORDER TESTS: PC Card #0...............................DETECTED Card Detect............................PASS Communication..........................PASS DOS Structure..........................PASS Sector Test (short)....................PASS PC Card #1...............................DETECTED Card Detect............................PASS Communication..........................PASS DOS Structure..........................PASS Sector Test (short)....................PASS DSP TESTS: Timing RAM...............................PASS Demod RAM...............................PASS Demod REG...............................PASS FIFOs....................................PASS SYSTEM TESTS: XILINX Interrupts... IRQ3 IRQ3 IRQ3 ...PASS Wide Bandwidth...........................PASS Narrow Bandwidth.........................PASS RSSI Filter..............................PASS Transmit.................................PASS SENSOR TESTS: H/W Operation............................PASS >pc2 Press any key to quit sensor display ... All Sensors are Internal Only. Heading Pitch Roll Up/Down Attitude Temp Ambient Temp PRESSURE 48.16ø -1.04ø 1.55ø Up 22.12øC 21.76øC -0.6 kPa >tg2013/05/01,18:00:00 >t? Available Commands: TB 00:00:00.00 --------- Time per Burst (hrs:min:sec.sec/100) TC 00000 --------------- Ensembles Per Burst (0-65535) TE 00:12:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100) TF 13/05/01,18:00:00 --- Time of First Ping (yr/mon/day,hour:min:sec) TG 2013/05/01,18:00:00 - Time of First Ping (CCYY/MM/DD,hh:mm:ss) TP 00:14.00 ------------ Time per Ping (min:sec.sec/100) TS 13/05/01,17:09:25 --- Time Set (yr/mon/day,hour:min:sec) TT 2013/05/01,17:09:25 - Time Set (CCYY/MM/DD,hh:mm:ss) TX 00:00:00 ------------ Buffer Output Period: (hh:mm:ss) T? --------------------- Display Time Help >cs