Deployment of Muskegon Buoy ADCP - July 13, 2010


[BREAK Wakeup A]
WorkHorse Broadband ADCP Version 51.37
Teledyne RD Instruments (c) 1996-2009
All Rights Reserved.

>ps0
  Instrument S/N:  6231
       Frequency:  614400 HZ
   Configuration:  4 BEAM, JANUS
     Match Layer:  10
      Beam Angle:  20 DEGREES
    Beam Pattern:  CONVEX
     Orientation:  UP
       Sensor(s):  HEADING  TILT 1  TILT 2  DEPTH  TEMPERATURE  PRESSURE
Pressure Sens Coefficients:
              c3 = -1.399378E-13
              c2 = +1.589760E-08
              c1 = +1.916898E-02
          Offset = -5.103810E+00

Temp Sens Offset:  -0.34 degrees C

    CPU Firmware:  51.37 [0]
   Boot Code Ver:  Required:  1.13   Actual:  1.13
    DEMOD #1 Ver:  ad48, Type:  1f
    DEMOD #2 Ver:  ad48, Type:  1f
    PWRTIMG  Ver:  85d3, Type:   4

Board Serial Number Data:
   C1  00 00 03 B4 45 BD  09 REC727-1000-03E
   AB  00 00 05 89 33 7D  09 PIO727-3000-00G
   DA  00 00 03 AC E1 B3  09 DSP727-2001-03G
   00  00 00 03 B5 D1 57  09 CPU727-2000-00J

>ol                             FEATURES
---------------------------------------------------------------------
Feature                                                     Installed
---------------------------------------------------------------------
BT-HA (High Accuracy)                                            No
Water Profile                                                   Yes
High Resolution Water Modes                                      No
LADCP/Surface Track/WM15                                         No
Wave Gauge Acquisition                                          Yes
Shallow Bottom Mode                                              No
High Rate Pinging                                                No
BT-RA (Reduced Accuracy)                                         No

See your technical manual or contact RDI for information on how to
install additional capability in your WorkHorse.

>?
Available Menus:
DEPLOY? ------------------ Deployment Commands
SYSTEM? ------------------ System Control, Data Recovery and Testing Commands

>deploy?
Deployment Commands:
CF = 11111 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec)
CK ----------------------- Keep Parameters as USER Defaults
CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY)
CS ----------------------- Start Deployment

EA = +00000 -------------- Heading Alignment (1/100 deg)
EB = +00000 -------------- Heading Bias (1/100 deg)
ED = 00170 --------------- Transducer Depth (0 - 65535 dm)
ES = 00 ------------------ Salinity (0-40 pp thousand)
EX = 11111 --------------- Coord Transform (Xform: Type,Tilts,3 Bm,Map)
EZ = 1111101 ------------- Sensor Source (C,D,H,P,R,S,T)

RE ----------------------- Recorder ErAsE
RN ----------------------- Set Deployment Name

TE = 01:00:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100)
TF = **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec)
TP = 00:09.00 ------------ Time per Ping (min:sec.sec/100)
TS = 10/07/13,15:24:10 --- Time Set (yr/mon/day,hour:min:sec)

WD = 111 100 000 --------- Data Out (Vel,Cor,Amp; PG,St,P0; P1,P2,P3)
WF = 0176 ---------------- Blank After Transmit (cm)
WN = 020 ----------------- Number of depth cells (1-128)
WP = 00400 --------------- Pings per Ensemble (0-16384)
WS = 0100 ---------------- Depth Cell Size (cm)
WV = 170 ----------------- Mode 1 Ambiguity Vel (cm/s radial)

>system?
System Control, Data Recovery and Testing Commands:
AC ----------------------- Output Active Fluxgate & Tilt Calibration data
AF ----------------------- Field calibrate to remove hard/soft iron error
AR ----------------------- Restore factory fluxgate calibration data
AX ----------------------- Examine compass performance
AZ ----------------------- Zero pressure reading

CB = 411 ----------------- Serial Port Control (Baud; Par; Stop)
CP # --------------------- Polled Mode (0 = NORMAL, 1 = POLLED)
CZ  ---------------------- Power Down Instrument

FC ----------------------- Clear Fault Log
FD ----------------------- Display Fault Log

OL ----------------------- Display Features List

PA ----------------------- Pre-Deployment Tests
PC1 ---------------------- Beam Continuity
PC2 ---------------------- Sensor Data
PS0 ---------------------- System Configuration
PS3 ---------------------- Transformation Matrices

RR ----------------------- Recorder Directory
RF ----------------------- Recorder Space used/free (bytes)
RY ----------------------- Upload Recorder Files to Host

>c?
CB = 411 ----------------- Serial Port Control (Baud [4=9600]; Par; Stop)
CC = 000 000 000 --------- Choose External Devices (x;x;x  x;x;x  x;x;SBMC)
CF = 11111 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec)
CK ----------------------- Keep Parameters as USER Defaults
CP = 0 ------------------- PolledMode (1=ON, 0=OFF;  BREAK resets)
CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY)
CS ----------------------- Go (Start Pinging)
CZ ----------------------- Power Down Instrument

>cd?
CD = 000 000 000 --------- Serial Data Out (Vel;Cor;Amp  PG;St;P0  P1;P2;P3)

>h?
Available Commands:

HB 05 -------------------- Number of Automatically Choosen Bins (20 Max)
HD 111000000 ------------- Waves Selected Data (Vel;Pres;Surf HPR;; ;;)
HF 00000 ----------------- Waves Flow Ctrl (Res;Res;Res;Ser;Rec)
HP 2400 ------------------ Number of Pings per Record
HR 01:00:00.00 ----------- Time between Wave Bursts (hh:mm:ss.ff)
HS 001,010,021,022,023 --- Bins selected for Directional wave data recording
HT 00:00:00.50 ----------- Time between Wave Pings  (hh:mm:ss.ff)
HV 001,010,021,022,023 --- Bins selected for Velocity Spectrum data recording
H? ----------------------- Display Waves Menu Help

>pd?
PD = 00 ------------------ Data Stream Select (0-18)

>t?
TE = 01:00:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100)
TF = **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec)
TG = ****/**/**,**:**:** - Time of First Ping (CCYY/MM/DD,hh:mm:ss)
TP = 00:09.00 ------------ Time per Ping (min:sec.sec/100)
TS = 10/07/13,15:24:50 --- Time Set (yr/mon/day,hour:min:sec)
TT = 2010/07/13,15:24:50 - Time Set (CCYY/MM/DD,hh:mm:ss)

>w?
WD = 111 100 000 --------- Data Out (Vel;Cor;Amp  PG;St;P0  P1;P2;P3)
WF = 0176 ---------------- Blank After Transmit (cm)
WN = 020 ----------------- Number of depth cells (1-255)
WP = 00400 --------------- Pings per Ensemble (0-16384)
WS = 0100 ---------------- Depth Cell Size (cm)
WV = 170 ----------------- Mode 1 Ambiguity Vel (cm/s radial)
WZ = 010 ----------------- Mode 5 Ambiguity Velocity (cm/s radial)

>wa?
WA = 255,001 ------------- False Target Threshold (Max)(0-255),[Start Bin]
>wb?
WB = 0 ------------------- Bandwidth Control (0=Wid,1=Nar)
>wc?
WC = 064 ----------------- Correlation Threshold
>we?
WE = 2000 ---------------- Error Velocity Threshold (0-5000 mm/s)
>wl?
WL = 001,005 ------------- Water Reference Layer:  Begin Cell (0=OFF), End Cell

>rr
Recorder Directory:
Volume serial number for device #0 is 18d2-1147

  _RDI_000 000        22219240 07-13-10   2:58:30p r  a [    2]

  Bytes used on device #0 = 22219240
Volume serial number for device #1 is 18d2-1147

  _RDI_000 000         4669419 09-29-09   6:21:22p r  a [    2]

  Bytes used on device #1 = 4669419
Total capacity   = 1023328256 bytes
Total bytes used =   26888659 bytes in 2 files
Total bytes free =  996433920 bytes

>rf
RF = 26888659,996433920 --- Rec space used (bytes), free (bytes)

>ck
[Parameters saved as USER defaults]

>pa

PRE-DEPLOYMENT TESTS

CPU TESTS:
  RTC......................................PASS
  RAM......................................PASS
  ROM......................................PASS
RECORDER TESTS:
  PC Card #0...............................DETECTED
    Card Detect............................PASS
    Communication..........................PASS
    DOS Structure..........................PASS
    Sector Test (short)....................PASS
  PC Card #1...............................DETECTED
    Card Detect............................PASS
    Communication..........................PASS
    DOS Structure..........................PASS
    Sector Test (short)....................PASS
DSP TESTS:
  Timing RAM...............................PASS
  Demod  RAM...............................PASS
  Demod  REG...............................PASS
  FIFOs....................................PASS
SYSTEM TESTS:
  XILINX Interrupts... IRQ3  IRQ3  IRQ3 ...PASS
  Wide Bandwidth...........................PASS
  Narrow Bandwidth.........................PASS
  RSSI Filter..............................PASS
  Transmit.................................PASS
SENSOR TESTS:
  H/W Operation............................PASS

>pc2

Press any key to quit sensor display ...

All Sensors are Internal Only.
Heading   Pitch    Roll   Up/Down    Attitude Temp   Ambient Temp   PRESSURE
324.47ø  -2.46ø   3.04ø     Up          25.05øC         8.37øC       165.8 kPa

>tg2010/07/13,16:00:00
>t?
TE = 01:00:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100)
TF = 10/07/13,16:00:00 --- Time of First Ping (yr/mon/day,hour:min:sec)
TG = 2010/07/13,16:00:00 - Time of First Ping (CCYY/MM/DD,hh:mm:ss)
TP = 00:09.00 ------------ Time per Ping (min:sec.sec/100)
TS = 10/07/13,15:28:14 --- Time Set (yr/mon/day,hour:min:sec)
TT = 2010/07/13,15:28:14 - Time Set (CCYY/MM/DD,hh:mm:ss)

>cs